WATER STORAGE

Dewars Ice Rink

Case study overview

Project Name

Live Active Ltd

UK

Tank Dimensions

3.5m x 2m x 2m

 

Tank Used

Sectional Tank

City Tanks

Tricel Solution

If you have a site that requires more specialist project management or a complex design, please contact our technical sales team who will be happy to assist you. Tricel is an approved supplier of water storage solutions throughout Ireland. All our tanks manufactured for drinking water have WRAS approval and are fully certified.

We would love to work on your next project, give our expert sales team a call for a quotation for your upcoming projects!

Request a quote for your project today!

THE CHALLENGE

Dewars Ice Rink

burst water tank

 

  • Dewars Ice Rink in Perth, Scotland.
  • Burst water storage tank with significant damage caused to the property.
  • The company required expert consultants to access the situation & offer recommendations for the correct type of water storage tank.
  • A fast turnaround due to water restrictions affecting the companies’ operational requirements.

Our Client contacted The Team in July of 2017 requiring an emergency site visit to access their burst water tank in the leisure complex. The job required manufacturing & replacing an existing water storage tank that had serviced the building for potable and non-potable water. The maintenance team were able to secure temporary water services in order to keep the building operational, but a site visit was required as a matter of urgency due to limited water supply & significate damage to the property.

A speedy resolution was required due to the company working off of temporary water supply which kept the operations functional but was not allowing them to operate at full capacity.

TRICEL SOLUTION

GRP Water Storage Tank Solution

After conducting a site visit to access the situation our surveyor was able to advise the original water tank burst due to each side of the tank compartments servicing different parts of the building. Each compartment was emptying at different rates; therefore, the division walls integrity was comprised. Over time this weakened the division wall and caused the tank to burst.

The existing tank measured a 3.5 x 2 x 2 meters, we recommended a replacement sectional tank of 3.5 x 2 x 2 tank with a lengthways division and division outlets.

We recommended placing extra connections on both compartment sides of the divider so that the sides of the tank could service the full building without draining one side at a time which resulted in the integrity of the tank being compromised, resulting in the burst tank.

Specification of the tank included hot pressed GRP panels, internally flanged base with external flanged walls and standard insulation.

From our first enquiry from Live Active Ltd in mid-July we designed, manufactured, delivered and installed the tank to WRAS specification by the 14th of August.

Consult with the experts in water storage solutions, incorrect tank specification will inevitably cause significant costs & extensive damage to property if the tank walls become comprised.

THE FINAL RESULT

From our first enquiry from Live Active Ltd in mid-July we designed, manufactured, delivered and installed the tank to WRAS specification by the 14th of August.

Our team specialise in water storing solutions for all industry types, we have been in business for over 50 years and have a wealth of knowledge & experience. We configure storage solutions to fit all space restrictions and have yet to find a project we cannot fulfil.